Description
AMPTRON® 12V 200Ah / 175A Lithium LiFePO4 Batteries are an alternative replacement (AR) for most applications currently using a deep cycle Gel, AGM or Flooded Lead Acid battery. The maximum continuous discharge current is 175A and peak discharge current 320A for 5 seconds.
These batteries are designed using only the highest quality components and are backed with our 4-year warranty. This includes the use of a robust Battery Management System (BMS), Aluminium encased prismatic cells, solid busbar connectors and internal protection to reduce movement and damaging vibrations. Our batteries can also be placed on their sides providing versatile installation options.
The integrated Battery Management System is designed to monitor, protect, and optimise each cell within the battery. The BMS maximises the performance of the battery by automatically balancing the cells and protecting them from over charging, over discharging, over temperature, and excessive charge or discharge currents. Our integrated BMS allows our batteries to be used as an alternative replacement for most applications requiring deep cycle batteries, however if the charging system does not support a Lithium charge profile, there are some compromises – please contact Amptron for more information.
Please click and read Battery warranty policy
Item
|
Specification
|
Description/Remark
|
Model
|
AT-LFP-12-200BV02
|
12V 200Ah / 175A Continuous Discharge Lithium LiFePO4 battery
|
Chemistry
|
Lithium Iron Phosphate (LiFePO4)
|
|
Battery dimensions
|
L-370mm x W-190mm x H-245mm
|
|
Weight
|
22kg
|
|
Cell type
|
3.2V 100Ah Prismatic cells
|
|
Battery module
|
8 pcs 3.2V 100Ah cells, 2 parallel strings of 4 cells in series
|
|
Casing material for single cell
|
Aluminium
|
|
Standard capacity(0.2C5A)
|
200Ah / 2560Wh
|
|
> 2000 cycles at 100% Depth of Discharge (DoD)
|
Cycle life
|
Under normal usage where the DOD is <80%, cycle life is expected to be up to 5000 cycles
|
Rated voltage
|
12.8V
|
Working voltage per cell: 3.2V
|
Charge voltage
|
14.4 – 14.6V
|
Max. charge voltage per cell: 3.65V
|
Cut-off volate
|
2.5V for lowest cell, nominal 10V
|
Cut-off is triggered when the first cell reaches 2.50V
|
Depth of discharge (DoD)
|
100%
|
Batteries can be discharged to 100% of the rated capacity
|
Standard charge current
|
50A
|
0.25C
|
Charging time
|
Approximately 5 hours
|
When charging from low voltage cut-off point
|
Optimum charge current range
|
20A (0.2C5A) to 100A (1C3A)
|
Cell max voltage < 3.9V
|
Rapid charging
|
Max. charge current 200A (1C3A)
|
Temperature increase falling within 15°C is normal. Over 15°C will affect the service life of the cells.
|
Max continuous discharge current
|
175A
|
0.875C, cell min voltage> 2.0v
|
Peak discharge current
|
320A
|
1.6C (5 seconds)
|
Discharge performance in normal temperature
|
20A (0.2C3A) ≥ 100%
1C3A ≥90% |
|
Operating temperatures
|
Standard 0℃~45℃
Discharge -20℃~65℃ Storage -20℃~45℃ |
|
Impedance (Max, at 1000Hz.)
|
≤ 45mΩ
|
|
Storage performance
|
Capacity can be kept ≥ 80% in storage for 12months
|
Battery should be kept at -20℃ ~ 45℃ where it’s dry, clean and well-ventilated.
|
Connecting Terminals Pos (+) & Neg (-)
|
M8
|
|
IP Rating (Ingress Protection)
|
IP65
|
Protected from total dust ingress & Protected from low pressure water jets from any direction |