Description
AMPTRON® 24V 150Ah Lithium LiFePO4 Batteries are an alternative replacement (AR) for most applications currently using a deep cycle Gel, AGM or Flooded Lead Acid battery. The maximum continuous discharge current is 175A and peak discharge current 320A for 5 seconds.
These batteries are designed using only the highest quality components and are backed with our 4-year warranty. This includes the use of a robust Battery Management System (BMS), Aluminium encased prismatic cells, solid busbar connectors and internal protection to reduce movement and damaging vibrations. Our batteries can also be placed on their sides providing versatile installation options.
The integrated Battery Management System is designed to monitor, protect, and optimise each cell within the battery. The BMS maximises the performance of the battery by automatically balancing the cells and protecting them from over charging, over discharging, over temperature, and excessive charge or discharge currents. Our integrated BMS allows our batteries to be used as an alternative replacement for most applications requiring deep cycle batteries, however if the charging system does not support a Lithium charge profile, there are some compromises – please contact Amptron for more information.
Please click and read Battery warranty policy
Item
|
Specification
|
Description/Remark
|
Model
|
AT-LFP-24-150BV01
|
24V 150Ah / 175A Lithium LiFePO4 battery
|
Chemistry
|
Lithium Iron Phosphate (LiFePO4)
|
|
Battery dimensions
|
L-520mm x W-268mm x H-228mm
|
L x W x H
|
Weight
|
31kg
|
|
Cell type
|
3.2V 100Ah Prismatic cells
|
|
Battery module
|
8 pcs 3.2V 150Ah cells, 1 parallel and 8 serial
|
|
Casing material for single cell
|
Aluminium
|
|
Standard capacity(0.2C5A)
|
24V 150Ah / 3840Wh
|
|
Cycle life
|
> 2000 cycles at 100% Depth of Discharge (DoD)
|
Under normal usage where the DOD is <80%, cycle life is expected to be up to 5000 cycles
|
Rated voltage
|
25.6V
|
Working voltage per cell: 3.2V
|
Charge voltage
|
28.8 V
|
Max. charge voltage per cell: 3.60V
|
Cut-off volate
|
2.5V for lowest cell, Nominal 20V
|
Cut-off is triggered when the first cell reaches 2.50V
|
Depth of discharge (DoD)
|
100%
|
Batteries can be discharged to 100% of the rated capacity
|
Optimum charge current
|
30A (0.2C5A)
|
Cell max voltage﹤3.9V
|
Charging time
|
Approximately 5 hours
|
When charging from low voltage cut-off point
|
Charge current range
|
30A (0.2C) to 136A (0.91C)
|
Cell max voltage < 3.9V
|
Rapid charging
|
Max. charge current 136A (0.91C)
|
Temperature increase falling within 15°C is normal. Over 15°C will affect the service life of the cells.
|
Max continuous discharge current
|
175A
|
1.17C
|
Peak discharge current
|
320A
|
2.13C (5 seconds)
|
Discharge performance in normal temperature
|
30A (0.2C) ≥ 100%
150A 1C ≥90% |
|
Operating temperatures
|
Standard 0℃~45℃
Discharge -20℃~65℃ Storage -20℃~45℃ |
|
Impedance (Max, at 1000Hz.)
|
≤ 20mΩ
|
|
Storage performance
|
Capacity can be kept ≥ 80% in storage for 12months
|
Battery should be kept at -20℃ ~ 45℃ where it’s dry, clean and well-ventilated.
|
Connecting Terminals Pos (+) & Neg (-)
|
M8
|
|
IP Rating (Ingress Protection)
|
IP65
|
Protected from total dust ingress & Protected from low pressure water jets from any direction |
HEAVY DUTY – BUILT IN BATTERY MANAGEMENT SYSTEM
AMPTRON® Lithium batteries use a built-in Battery Management System (BMS) designed to automatically disconnect the charging or discharging circuits to prevent damage to the cells and internal electronics from abnormal operation and helps to ensure safe and accurate operation of the battery.
THE BMS PROTECTION FEATURES INCLUDE:
- Low Voltage Protection Switch – Automatically disconnects the discharge circuit to prevent damage to the cells if the battery drains below a pre-set voltage.
- Over Voltage Protection Switch – Automatically disconnects the charging circuit to prevent damage to the cells if the battery is being charged above a pre-set maximum voltage.
- Short Circuit and Over Current Protection Switch – Automatically disconnects the discharge circuit if the load draws currents above pre-set limits.
- Reverse Polarity Protection Switch – Automatically disconnects the charge and discharge circuits if a reverse polarity condition is detected.
- Thermal protection – Built-in thermal sensors will automatically disconnect the charge and discharge circuits when excessive temperatures are detected.
CELL BALANCING
The BMS balances the cells through top-end balancing and will discharge cells that exceed 3.65V during charging.
INTERNAL CELL SAFETY
THERMAL FUSE: Our latest prismatic cell technology is manufactured with an internal thermal safety fuse between the anode and cathode that will break and disconnect in the unlikely event the cell would begin to overheat.
SAFETY VENT: Each cell has a high-pressure safety vent that will flip open to release energy and prevent explosion.
FLAME RETARDANT ELECTROLYTE: Our cells are manufactured with a flame retardant additive in our electrolyte.